Fire Safety Supplier Gent/SMS FP585 Conventional Panel Less Batteries – 2 Zones







Fire Safety Supplier Gent/SMS FP585 Conventional Panel Less Batteries – 2 Zones


Fire Safety Supplier Gent/SMS FP585 Conventional Panel Less Batteries – 2 Zones

Introduction

Welcome to our article on the Gent/SMS FP585 Conventional Panel Less Batteries – 2 Zones. This fire safety panel is designed to provide reliable protection for your building. With its compliance to European standards and compatibility with various installations, it offers peace of mind and efficient fire detection. Read on to learn more about its features and specifications.

Main Features

  • Complies fully with the European standard EN54 Parts 2 & 4
  • Can be used on installations meeting BS 5839
  • Integral power supply
  • Two alarm sounder circuits
  • Two auxiliary relay contacts
  • Zone disablement facility
  • Convenient, one-man test and commission facility
  • Simple system design

Technical Specifications

  • Maximum load per zone: 3mA
  • Number of sounder circuits: 2
  • Max. sounder circuit load: 0.5A per circuit (total load not to exceed 1A)
  • Batteries (not included): 2 x 12V, 2.1 Ah
  • Aux. relay contacts: 1 N/O and 1 N/C pair, 1A at 24V
  • Relevant standard: EN54 Parts 2 and 4
  • Approvals: LPCB approved to EN54 Parts 2 and 4
  • Weight (with batteries): 5.8kg
  • Cable entry: 13 Top and 13 Rear
  • Cable type: BS 6387, 2 core, min 1.5mm2 CSA
  • Class change facility: via normally open push button switch located no more than 100m from panel
  • Temperature: Indoor 0 – 40oC
  • Manufacturer’s part number: 75585-02NMB

Frequently Asked Questions

1. Can this panel be used in commercial buildings?

Yes, the Gent/SMS FP585 Conventional Panel is suitable for use in commercial buildings that meet the BS 5839 standard.

2. How many alarm sounder circuits does it have?

This panel features two alarm sounder circuits, providing efficient sound distribution in case of fire.

3. What is the maximum load per zone?

The maximum load per zone is 3mA, ensuring proper functioning of the fire detection system.

4. Are batteries included with the panel?

No, batteries are not included. You will need to purchase 2 x 12V, 2.1 Ah batteries separately.

5. Is the panel easy to test and commission?

Yes, the Gent/SMS FP585 Conventional Panel features a convenient one-man test and commission facility, making the process hassle-free.

Thank you for reading our article on the Gent/SMS FP585 Conventional Panel Less Batteries – 2 Zones. For more information or to purchase this fire safety solution, please contact our fire safety supplier.